Model : Fluke 52-2
The Fluke 52 Series II Digital Datalogging thermometers offers high accuracy with fast response time to capture your measurement and show trend, in a rugged, handheld test tool.
This Fluke 52 II has dual input, using relative time.
Features and benefits of the Fluke 52-2 series
- Relative time clock on MIN, MAX, and AVG provides a time reference for major events
- Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
- Measures J, K, T, and E-types of thermocouples
- Readout in ºC, ºF, or Kelvin (K)
- Splash and dust resistant case protected by impact absorbing holster
- User-friendly front panel is easy to set up and operate
- Sleep mode increases battery life; typical 1000-hour battery life
- Battery door allows easy battery replacement without breaking the calibration seal
- Optional ToolPak accessory allows the thermometer to hang from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation.
- 3 year warranty
- Large backlit dual display shows any combination of T1, T2 (52 and 54 only), T1-T2 (52 and 54 only), plus MIN, MAX, or AVG.
- RPM measurements with optional inductive pickup
- Temperature measurements with optional temperature probe
|
Specifications |
Temperature accuracy | Above -100 °C: | J, K, T, E, and N-type: ±[0.05% + 0.3°C]* | | R and S-type: ±[0.05% + 0.4°C]* | Below -100 °C: | J, K, E, and N-types: ±[0.20% + 0.3°C]* | | T-type: ±[0.50% + 0.3°C] | |
Temperature Range | J-type: | -210 °C to 1200 °C | K-type: | -200 °C to 1372 °C | T-type: | -250 °C to 400 °C | E-type: | -150 °C to 1000 °C | N-type: | -200 °C to 1300 °C * | R and S-type: | 0 °C to 1767 °C * | |
Temperature scale | |
Applicable standards | |
Display Resolution | | 0.1 °C, 0.1 K < 1000 | | 1°C, 1 K >=1000 | |
Note | * | Only the Fluke Models 53 II and 54 II thermometers are capable of measuring N, R, and S-type thermocouples. | |
Environmental Specifications |
Operating Temperature | |
Storage Temperature | |
Humidity (Without Condensation) | | 0% to 90%; 0 °C to 35 °C | | 0% to 70%; 0 °C to 50 °C | |
Safety Specifications |
Overvoltage category | | CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 | |
Agency Approvals | |
Mechanical & General Specifications |
Size | | 173 mm L x 86 mm W x 38 mm | |
Weight | |
Batteries | | 3 AA batteries; typical 1000-hour life | |
Fluke 52-2 include:
*Impact absorbing holster
*Two 80PK-1 beaded probe thermocouples
This product was added to our catalog on Thursday 01 January, 1970.