Confidently take reliable readings with the True-rms, Fluke 355 and 353 digital clamp meters; the tools of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.
Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.
Features and benefits of the Fluke 355
- Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
- The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
- CAT IV 600 V, CAT III 1000 V rating for added user protection
- In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
- High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple tests with only one tool (355 only)
- Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter. (355 only)
- Accurately measure frequency up to 1 kHz for optimum troubleshooting
- Quickly analyze readings using the MIN, MAX, and AVG functions
- A large backlit display allows for easy visibility in low-lit areas
- Use the display hold feature to capture readings even when the display cannot be viewed
- Use the low-pass filter to smooth out noisy loads and stabilize readings
Electrical specifications | Current measurement dc and ac 10 Hz to 100 Hz | Range : 40 A | Resolution: 10 mA Accuracy, A: 1.5 % rdg + 15 digits Trigger Level for Inrush: 0.50 A Trigger Level for Hz Filter OFF: 2.50 A Trigger Level for Hz Filter ON: 0.50 A | Range : 400 A | Resolution: 100 mA Accuracy, A: 1.5 % rdg + 5 digits Trigger Level for Inrush: 5.0 A Trigger Level for Hz Filter OFF: 2.5 A Trigger Level for Hz Filter ON: 2.5 A | Range : 2000 A; 1400 ac rms | Resolution: 1 A Accuracy, A: 1.5 % rdg + 5 digits Trigger Level for Inrush: 5 A Trigger Level for Hz Filter OFF: 8 A Trigger Level for Hz Filter ON: 8 A | | Crest Factor (50/60 Hz) | Range : 40 A | Crest Factor* : 2 @ 33 A, 2.4 @ 27 A | Range : 400 A | Crest Factor* : 2 @ 330 A, 2.4 @ 270 A | Range : 2000 A; 1400 ac rms | Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A | | Current measurement ac 100.1 Hz to 1 kHz | Range : 40 A | Resolution: 10 mA Accuracy > 10 A : 3.5 % rdg + 15 digits Trigger Level for Inrush: 0.50 A Trigger Level for Hz Filter OFF : 2.50 A Trigger Level for Hz Filter ON : 0.50 A | Range : 400 A | Resolution: 100 mA Accuracy > 10 A : 3.5 % rdg + 5 digits Trigger Level for Inrush: 5.0 A Trigger Level for Hz Filter OFF : 2.5 A Trigger Level for Hz Filter ON : 2.5 A | Range : 2000 A; 1400 ac rms | Resolution: 1 A Accuracy > 10 A : 3.5 % rdg + 5 digits Trigger Level for Inrush: 5 A Trigger Level for Hz Filter OFF : 8 A Trigger Level for Hz Filter ON : 8 A | | Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz (600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.) | Range : 4 V | Resolution: 1 mV Accuracy: 1 % rdg + 10 digits Trigger Level for Hz Filter OFF: 0.050 V Trigger Level for Hz Filter ON: 0.050 V | Range : 40 V | Resolution: 10 mV Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 0.25 V Trigger Level for Hz Filter ON: 0.25 V | Range : 400 V | Resolution: 100 mV Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V | Range : 600 V ac rms | Resolution: 1 V Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V | Range : 1000 V dc | Resolution: 1 V Accuracy: 1 % rdg + 5 digits | | Voltage measurement (355 only) ac 100.1 Hz to 1 kHz (600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.) | Range: 4 V | Resolution: 1 mV Accuracy: 3 % rdg + 10 digits Trigger Level for Hz Filter OFF: 0.050 V Trigger Level for Hz Filter ON: 0.050 V | Range: 40 V | Resolution: 10 mV Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 0.25 V Trigger Level for Hz Filter ON: 0.25 V | Range: 400 V | Resolution: 100 mV Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V | Range: 600 V ac rms | Resolution: 1 V Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V | | Ohms measurement (355 only) | Range: 400 ? | Resolution: 0.1 ? Accuracy: 1.5 % + 5 digits | Range: 4 k? | Resolution: 1 ? Accuracy: 1.5 % + 5 digits | Range: 40 k? | Resolution: 10 ? Accuracy: 1.5 % + 5 digits | Range: 400 k? | Resolution: 100 ? Accuracy: 1.5 % + 5 digits | | Continuity beeper (355 only) | | On at ≤ 30 ? | | Off at ≥ 100 ? | | Frequency measurement | Measurement range | 5.0 Hz to 1 kHz | Resolution | 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) | Accuracy – 5.0 Hz to 100 Hz | 0.2 % + 2 counts | Accuracy – 100.1 Hz to 1 kHz | 0.5 % + 5 counts | Trigger level | Refer to current and voltage tables | | *Add 2 % to error spec for CF > 2 General specifications | Batteries | | Six 1.5 V AA NEDA 15 A or IEC LR6 | | Battery life (with typical usage, backlight off) | | Test leads | | Weight | | Jaw size | This product was added to our catalog on Friday 01 August, 2014.
Who's Online
There currently are 702 guests online.
Your IP Address is: 3.149.25.117
| | | |