Manufacturers

Hioki 3290-10 AC/DC Clamp On Hitester

  • Model: Hioki 3290-10 AC/DC
  • Shipping Weight: 0.545kg
  • Manufactured by: Hioki

RM3,076.00

Add to Cart:

Hioki 3290-10 Feature :-

All the Functions You Need for Measurement at DC or 1Hz and Up

http://www.hioki.com/share/space.gif

·         Choice of three sensors (Example combinations)
Measure up to 100 A, 200 A, or 2000 A rated current

·         Correct measurement for inverter current with AC+DC mode and True RMS rectification

·         Choice of output (Simultaneous output) Effective value, waveform, frequency, and integral value output

·         Choice of response time with three steps

·         Model 3290-10 only with integral current measurement, operating time rate measurement

 

Hioki 3290-10 Specification

Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)

 

 

3290

3290-10

Measurement method

DC, AC+DC (True RMS), AC (True RMS/ Average rectified)

DC, AC+DC (True RMS), AC (True RMS)

Peak value display

Absolute value (of waveform peak)

Polarities independently (±peak value of waveform, in DC mode)

Separate AC from DC output

Separate constituent element of AC, DC

None

Output (terminal 1)

Current waveform or true RMS value (2 V / setting range), Frequency value (1 VDC / setting range)

Current waveform or true RMS value (2 V / setting range)

Output (terminal 2)

Rms current/Low-battery warning switch

Current integral value (1 VDC / setting range)

Integral current measurement

None

±, +, - integral, average value

Rate measurement

None

Operating time rate, total measurement time

Timer settings

None

99 hr, 59 min. (for repeated up to 20 times)

Data storage

None

Peak, integral value, operating time rate, or other

Basic accuracy at DC current

20.00/ 100.0A (using the CT9691 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
20.00/ 200.0A (using the CT9692 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
200.0/ 2000A (using the CT9693 sensor): ±1.8 % rdg. ±1.0 A/ ±5 A

Basic accuracy at AC current
(45 to 66 Hz)

20.00/ 100.0A (using the CT9691 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
20.00/ 200.0A (using the CT9692 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
200.0/ 2000A (using the CT9693 sensor): ±1.3 % rdg. ±0.8 A/ ±3 A

Voltage measurement

None

Frequency measurement

1.00Hz to 1000Hz, Basic accuracy: ±0.3% rdg. ±1dgt.

Crest factor

2.5 or later, or rated peak value of sensor

Frequency characteristic

DC, or 1 Hz to 1 kHz (accuracy guaranteed range)
At monitor output: based on the using sensor

Other functions

Selectable of response time, filter (fc=550 Hz)

Power supply

LR6 (AA) alkaline batteries × 4, Continuous use : 22 hr, or AC adapter 9445-02/-03 (The 3290-10 only: external power supply possible)

Dimensions, mass

155 mm (6.10 in) W × 98 mm (3.86 in) H × 47 mm (1.85 in) D, 545 g (19.2 oz)

Supplied accessories

Carrying strap ×1, LR6 (AA) alkaline batteries × 4, Instruction manual ×1


This product was added to our catalog on Wednesday 15 January, 2014.

Who's Online

There currently are 295 guests online.
Your IP Address is: 3.145.108.43
Copyright © 2024 Techno Tools*** About Us***mobile link***Desktop link