Prova 6600 Power Clamp Meter, (3 Phase / 1 Phase) Features :-
*3 f 4W, 3 f 3W, 3 f Balanced, 1 f 2W, and 1 f 3W Power Measurement.
*AC+DC true power, and True RMS AC Voltage and Current
*AC+DC 2000A, AC 600V, DC 800V
*AC+DC 1200KW(1 f ), AC+DC 2000KW (3 f )
*Dual Display V+Hz, A+Hz, W+PF, KVA+KVAR, V+A
*Phase Angle Measurement
*3 f RST(L1L2L3) Sequence Indication.
*Memory of 4 records.
*DCA/DCW Auto Zero when power clamp powering on.
*AC/DC Auto Detection.
*Auto range.
Prova 6600 Power Clamp Meter Specification
AC+DC True Power (PF 0.2-1.0, 3 Φ 3W, 3 Φ 4W, 1 Φ 2W, and 1 Φ 3W) |
Range | Resolution | Accuracy(of rdg) | Input Range | 0-99.9KW | 0.1KW | +/- 2.0% +/- 0.05KW | AC 600V, DC 800V, ACA/DCA 2000A | 100-999.9KW | 0.1KW | +/- 2.0% +/- 0.5KW | AC 600V, DC 800V, ACA/DCA 2000A | 1000-1200KW | 1KW | +/- 2.0% +/- 5KW | AC 600V, DC 800V, ACA/DCA 2000A |
|
AC+DC True Power (Power Factor 0.2-1.0, 3 Φ Balanced Power) |
Range | Resolution | Accuracy (or rdg) | Input Range | 0-99.99KW | 0.01KW | +/- 2.0% +/- 0.5KW | AC 600V, DC 800V, ACA/DCA 2000A | 100-999.9KW | 0.1KW | +/- 2.0% +/- 0.5KW | AC 600V, DC 800V, ACA/DCA 2000A | 1000-1200KW | 1KW | +/- 2.0% +/- 5KW | AC 600V, DC 800V, ACA/DCA 2000A |
POWER FACTOR (PF) PF=KW/KVA |
|
AC+DC Voltage (True RMS, Crest Factor<4, Autorange, Overload Protection 800VAC for all ranges) |
Range | Resolution | Accuracy(of reading) | Input Impedance | DC, 50/60Hz | 40-400Hz | 0-200A | 0.1V | +/- 1.5% +/- 5 dgts | +/- 2.0% +/- 5 dgts | 10M Ω | 200-500A | 0.1V | +/- 1.5% +/- 5 dgts | +/- 2.0% +/- 5 dgts | 10M Ω | 500-600VAC 500-800VDC | 1V | +/- 1.5% +/- 5 dgts | +/- 2.0% +/- 5 dgts | 10M Ω |
|
AC+DC Current (True RMS, Crest Factor<4) |
Range | Resolution | Accuracy(of reading) | Overload Protection | DC, 50/60 Hz | 40-400Hz | 0-200A | 0.1A | +/- 1.5% +/- 5 dgts | +/- 2.0% +/- 5 dgts | AC 3000A | 200-500A | 0.1A | +/- 2.0% +/- 5 dgts | +/- 2.5% +/- 5 dgts | AC 3000A | 500-2000A | 1A | +/- 2.5% +/- 5 dgts | +/- 3.0% +/- 5 dgts | AC 3000A |
AC+DC KVA (Apparent Power) (KVA)=VxA/1000 AC+DC KVAR (Reactive Power) (KVAR)= |
|
Phase Angle (must zero current reading before measurement) |
Range | Accuracy | Sensitivity | Remark | 50/60Hz | +/- 2.0 ° | V>100V, A>10A | Zero Crossing Detection |
|
Frequency (if<10 Hz, Hz=0) |
Range | Accuracy | Sensitivity | 50/60Hz | +/- 2dgts | V: >1V, A: >5A | 10-400Hz | +/- 0.5% +/- 2dgts | V: >1A, A: >5A |
|
Conductor Size | Cable f 55mm. (approx.) Bus Bar 65mm(D)x24mm(W) | Battery Type | 9V | Display | 2x4 Digits Dual Display LCD | Range Selection | Auto | Overload Indication | OL | Power Consumption | 28mA (approx.) | Low battery Indication |
| Sampling Time | 0.5 sec. (V and A) 1.6 sec. (W) | Operating Temperature | 4 o to 50 o C | Operating Humidity | Less than 85% relative | Altitude | up to 2000M | Storage Temperature | -20 o C to 60 o | This product was added to our catalog on Thursday 01 August, 2013.
Who's Online
There currently are 649 guests online.
Your IP Address is: 18.116.14.48
|
|