Manufacturers

Kyoritsu 2432 Leakage Clamp Meter

  • Model: KE 2432
  • Shipping Weight: 0.29kg
  • Manufactured by: KYORITSU

RM2,980.00

Add to Cart:

High Sensitive Model

Frequency Selector Switch to eliminate the effect of harmonics.

Three AC current ranges : 4mA/40mA/100A

 

 

AC A
(50/60Hz)

4/40mA/100A
|±1%rdg±5dgt (4/40mA)
|±1%rdg±5dgt (0~80A)
|±5%rdg (80.1~100A)

AC A
(WIDE)

4/40mA/100A
|±1%rdg±5dgt [50/60Hz],
|±2.5%rdg±10dgt [20Hz~1kHz] (4/40mA)
|±1%rdg±5dgt [50/60Hz],
|±2.5%rdg±10dgt [40Hz~1kHz] (0~80A)
|±5%rdg [50/60Hz],
|±10%rdg [40Hz~1kHz] (80.1~100A)

Frequency Response

20Hz~1kHz (40Hz~1kHz:100A)

Maximum
Circuit Voltage

600V AC/DC (between line/neutral)
300V AC/DC (against earth)

Conductor Size

Ø40mm max.

Safety Standard

IEC 61010-1 CAT.III 300V Pollution Degree 2
IEC 61010-2-032

Effect of External
Stray Magnetic Field

2mA AC approx. in proximity to a 15mm-dia
conductor carrying 100A AC

Withstand Voltage

3700V AC for 1 minute

Response Time

Approx. 2 seconds

Power Source

Two R03 or equivalent (DC1.5V) batteries

Dimensions

185(L) × 81(W) × 32(D)mm

Weight

290g approx.

Accessories

9052 (Carrying Case)
R03 (1.5V) × 2
Instruction Manual

Optional

8008 (Multi-Tran)*

 

 

* This Multi-Tran can not be used for leakage current measurement

This product was added to our catalog on Thursday 01 January, 1970.